Skip to main content
  1. 先に進む前に、ケーブルスリーブをひねる必要があります。この作業により、プリント中に中のケーブルが飛び出てきてしまうのを防ぐことができます。
    • 先に進む前に、ケーブルスリーブをひねる必要があります。この作業により、プリント中に中のケーブルが飛び出てきてしまうのを防ぐことができます。

    • 指をうまく使って、スリーブをやさしくひねり、数周のループができるようにします。(中のケーブルはひねりません。)

    • スリーブをひねることで、スリーブ自体の長さが効果的に縮まります。次のステップにおいて、スリーブを逆に少しだけひねり戻し、長さを確保する必要があるかもしれません。

  2. Let's make sure the cables from the hotend aren't in contact with the heatbed.
    • Let's make sure the cables from the hotend aren't in contact with the heatbed.

    • By rotating the threaded rods at the same time, lower manually the X-axis down until the nozzle is almost touching the heatbed.

    • In case the P.I.N.D.A. sensor touches the bed before the nozzle, move it up slightly.

    • Ensure there is a gap between the screw in the heatbed and the surface of the hotend cables. The gap should be 2-3 millimetres, the steel sheet will add another 1 mm.

    • In case the cables are rubbing against the screw, adjust them (push them up in the extruder)

    • In case you are unable to adjust the cables, unscrew the M3x10 screw and use a spare M3n nut to shorten the length of the thread. Then place the screw back.

  3. ナイロンフィラメントを穴に差し込みます。 フィラメントがモーターの配線を押し込んでいないことを確認してください。この状態は、フィラメントが長すぎることを示しています。この場合には、スリーブをねじって、フィラメントを押し戻す必要があります。 スリーブをホルダーの中にずらします。このとき、ホルダーの中にスリーブが最低でも ホルダーの高さの 3/4 だけ入っていることを確認してください。
    • ナイロンフィラメントを穴に差し込みます。

    • フィラメントがモーターの配線を押し込んでいないことを確認してください。この状態は、フィラメントが長すぎることを示しています。この場合には、スリーブをねじって、フィラメントを押し戻す必要があります。

    • スリーブをホルダーの中にずらします。このとき、ホルダーの中にスリーブが最低でも ホルダーの高さの 3/4 だけ入っていることを確認してください。

    • 再度、フィラメントがモーターの配線を押し込んでいないことを確認してください。もし必要であれば、スリーブをねじって、フィラメントを押し戻してください。

    • Extruder-cable-clip と 2本 の M3x10 ネジ を使って、ケーブルの束を固定します。

  4. IMPORTANT: Connecting the filament sensor cable properly is crucial. If you don't follow the instructions properly, you will burn the sensor!!! DON'T CONNECT THE CABLE NOW, wait for the next step!!! To ensure the cable is connected properly we are introducing a new part called "plug-aligner", which is now distributed with all MK3S printers leaving the factory.
    • IMPORTANT: Connecting the filament sensor cable properly is crucial. If you don't follow the instructions properly, you will burn the sensor!!!

    • DON'T CONNECT THE CABLE NOW, wait for the next step!!!

    • To ensure the cable is connected properly we are introducing a new part called "plug-aligner", which is now distributed with all MK3S printers leaving the factory.

    • In case the plug-aligner falls out during the transport, gently push it back in. The notch should be oriented up, like in the picture.

    • There are two rows of pins in the connector:

    • Lower row (for MK3S) use these pins to connect the IR-sensor.

    • Upper row (for MMU2S) these pins won't be used in this manual.

  5. Connect the remaining cables from the Extruder: Extruder heater (red cable pair | Nr. 1)
    • Connect the remaining cables from the Extruder:

    • Extruder heater (red cable pair | Nr. 1)

    • Hotend fan (black cable | Nr .2)

    • Print fan (red label | Nr. 3)

    • IR-sensor with two wires facing to the right (Nr. 4) !!! USE THE LOWER ROW !!!

    • Extruder motor (yellow label with "E" | Nr. 5)

    • Extruder thermistor (green/yellow label | Nr. 6)

    • P.I.N.D.A. probe cable (Nr. 7)

  6. 写真の通りに、それぞれのコネクタが取り付けられているかどうかを確認してください。 フィラメントセンサーの配線全てがしっかりとピンに接続されていることを再度確認してください! コネクターがずれてしまっていると、センサーに修理不能なダメージを与えることがあります。
    • 写真の通りに、それぞれのコネクタが取り付けられているかどうかを確認してください。

    • フィラメントセンサーの配線全てがしっかりとピンに接続されていることを再度確認してください! コネクターがずれてしまっていると、センサーに修理不能なダメージを与えることがあります。

  7. For this step, please prepare: M3x40 screw (1x)
    • For this step, please prepare:

    • M3x40 screw (1x)

    • Close the Einsy-door.

    • Make sure that no wire is pinched!

    • Tighten the M3x40 screw.

  8. Congratulations, you've just upgraded the Original Prusa i3 MK3S 3D printer!
    • Congratulations, you've just upgraded the Original Prusa i3 MK3S 3D printer!

    • You're almost there... Just finish the chapter 5. Preflight check

Finish Line